Q2000-C Proximity Card + Password Access Control

Q2000-C Proximity Card + Password Access Control

Model No.︰Q2000-C

Brand Name︰Erfid

Country of Origin︰China

Unit Price︰-

Minimum Order︰-

Inquire Now

Product Description

Q2000-C/M Single Door Access Control, Support EM-ID/Mifare or Password Mode

 

 

Build-in access controller and Digital keyboard Manage

Operating Mode: Proximity Card Or password OR Card + Password

Specification

Supply Voltage: DC12V

Working Current: less than 1000 mA

Static current: less than 80 mA

User capacity: 200/800 Card and 200 passwords

Proximity distance: more than 5CM

Support Card type: EM-ID (125 KHz) or Mifare Card

Operation Temperature: -10 C-70 C

Operation Humidity: 10%-90%

 

Program Method

1. Proximity Card AND password Opening Door Mode.

*Press Key # four times, the Buzzer make long sound BI, POWER (Red), OK (Green), Mode (Yellow) is on at the same time.

*Input 5 digits PIN (Default Password is 12345), OK (Green) is off. The machine enters Making Program Status.

*Press key 2, MODE light (Yellow) is on, POWER (Red) and OK (Green) light are off.

*Input 4 character password to open a door (Such as: 0008), the POWER (Red) and OK light (Green) flash.

*Read the user card that needs log in, a sound BI will be heard, POWER light (Red) is off, OK (Green) and MODE light (Orange) are on, the user card is registered successfully.

*Input 4 digits PIN for opening the door, OK (Green) is off, POWER (Red) is on, which showing PIN is registered.

*Press key 7, MODE (Yellow) and POWER light (Red) are bright, OK light (Green) is off.

*Press key 1, a short sound BI will be heard, MODE light is bright, which shows setting is successful.

*Press Key 6 to Exit programming status.

 Opening Door Note: First punching the card, and then input the password in 30 seconds.

 2. Proximity Card OR password Opening Door Mode.

*Press Key # four times, the Buzzer makes long sound BI, POWER: (Red), OK (Green), Mode (Yellow) is on at the same time.

*Input 5 digits PIN (Default Password is 12345), OK (Green) is off. The machine enters Making Program Status.

*Press key 2, MODE light (Yellow) is on, POWER (Red) and OK (Green) light are off.

*Input 4 character password to open a door (Such as: 0008), the POWER (Red) and OK light (Green) flash.

*Read the user card that needs log in, a sound BI will be heard, POWER light (Red) is off, OK(Green) and MODE light (Orange) are on, the user card is registered successfully.

*Input 4 digits PIN for opening the door, OK (Green) is off, POWER (Red) is on, which showing PIN is registered.

*Press key 7, MODE (Yellow) and POWER light (Red) are bright, OK light (Green) is off.

*Press any key except key 1, the Buzzer make a short sound BI.MODE light (Yellow) is bright; the setting for access control is card or password for opening a door.

*Press Key 6 to Exit programming status.

Other Setting:

*Change Program Operating Password

*Press key 1, The MODE (Yellow) light is on, POWER (Red), OK (Green) light is off.

*Input PIN as your will (Example, 23456), the Buzzer make a short sound of BI, OK (Green) is on, POWER (Red), MODE (yellow) is on, PIN has changed successfully.  Note: The PIN should be kept; you will need it to enter the Making Program Mode next time. If PIN forgotten, please execute Machine Initial Step.

Delete the single user card and password

*Press key 3, MODE light (yellow) is bright, POWER (Red) and OK (green) light are off.

*Input 4 character user series No that needs to be deleted. (Series No on card, such as: 0008), a sound BI will be heard. This means the deletion is successful.

*Delete all registered cards and passwords in the machine

 *Press key 4, BI will be heard twice. All the registered cards and passwords are deleted.

 

Open Door Time Setting

 *Press key 5, MODE light (Yellow) is bright, POWER (Red) and OK (Green) are off.

*Input 2 character as the door open time (Such as: 05, means that the door open time is 5 second), sound BI will be heard twice, this means the door open time setup is successful.

 Note: The default open time is 3 second



Product Image